Regulations and standards
Seven frameworks ask for resilience to be tested or shown. This page says what each asks, and which kind of test gives evidence for it. Every control, with its strength and where Tumult keeps the evidence, is in Regulatory mapping.
Evidence, not compliance. A run gives evidence toward a control. Passing runs do not prove compliance and are no legal attestation. An auditor decides compliance against the official text.
The frameworks
| Framework | Applies to | What it asks |
|---|---|---|
| DORA, Regulation (EU) 2022/2554 | EU financial entities | A testing programme (Art. 24), yearly tests of the systems behind critical or important functions (Art. 24(6)), tests such as scenario, performance and end-to-end tests (Art. 25), tested continuity, response and recovery plans (Art. 11), tested backup and restore (Art. 12) |
| NIS2, Directive (EU) 2022/2555 | EU essential and important entities | Measures for business continuity, such as backup and disaster recovery (Art. 21(2)(c)), incident handling (Art. 21(2)(b)), a way to assess that the measures work (Art. 21(2)(f)) |
| ISO 22301:2019 | Voluntary, often in contracts | A programme of exercises and tests, with a report after each (Clause 8.5) |
| ISO 27001:2022 | Voluntary, often in contracts | ICT continuity planned and tested (A.5.30), security kept during a disruption (A.5.29) |
| SOC 2, Trust Services Criteria 2017 | Voluntary, often in contracts | Recovery from incidents (CC7.5), response to incidents (CC7.4), monitoring for anomalies (CC7.2) |
| PCI DSS 4.0 | Anyone who handles card data | The incident response plan tested at least once every 12 months (Req. 12.10.2) |
| Basel Committee (BCBS) | Banks | Continuity exercises under severe but plausible scenarios (Principles for Operational Resilience, Principle 4) |
Which kind of test counts
Each cell names the controls where a kind gives its main evidence, as Regulatory mapping describes the evidence.
| Framework | Chaos | Robustness | Disaster recovery | Load and performance |
|---|---|---|---|---|
| DORA | Art. 25 | Art. 25 | Art. 11, Art. 12 | Art. 25 |
| NIS2 | Art. 21(2)(b), Art. 21(2)(f) | Art. 21(2)(f) | Art. 21(2)(c) | |
| ISO 22301 | Clause 8.5 | Clause 8.5 | ||
| ISO 27001 | A.5.29 | A.5.29 | A.5.30 | |
| SOC 2 | CC7.4 | CC7.5 | ||
| PCI DSS | Req. 12.10.2 | |||
| Basel | Principle 4 | Principle 4 |
Every kind counts toward DORA Art. 24 and Art. 24(6): a programme of dated tests. DORA Art. 12 counts only a test that restores something. The spans and metrics of a run count toward SOC 2 CC7.2.
What overlaps
In this mapping, six of the seven have a control on recovery or continuity. One DR test with a measured RTO gives evidence toward all six.
flowchart LR
accTitle: One DR test, six recovery controls
accDescr: A DR test that measures its RTO gives evidence toward DORA Art. 11, NIS2 Art. 21(2)(c), ISO 22301 Clause 8.5, ISO 27001 A.5.30, SOC 2 CC7.5 and BCBS Principle 4.
test["A DR test<br/>with a measured RTO"] --> dora["DORA<br/>Art. 11"]
test --> nis2["NIS2<br/>Art. 21(2)(c)"]
test --> iso22301["ISO 22301<br/>Clause 8.5"]
test --> iso27001["ISO 27001<br/>A.5.30"]
test --> soc2["SOC 2<br/>CC7.5"]
test --> bcbs["BCBS<br/>Principle 4"]
- Incident response. A controlled fault exercises it for NIS2 Art. 21(2)(b), SOC 2 CC7.4 and PCI DSS Req. 12.10.2.
- One run, many frameworks. The
regulatoryblock of an experiment lists every framework the run counts for, such asframeworks[2]: DORA, NIS2. See Tag an experiment.
What differs
- Law or choice. DORA and NIS2 are EU law. ISO 22301, ISO 27001 and SOC 2 are voluntary and often in contracts. PCI DSS applies to anyone who handles card data, and the BCBS principles to banks.
- How often. Three controls of the mapping set a period: tests at least yearly (DORA Art. 24(6)), a TLPT at least every three years (DORA Art. 26), and an incident response test at least once every 12 months (PCI DSS Req. 12.10.2).
- Load. In this mapping, only DORA Art. 25 names performance testing, so load tests count for DORA alone.
- Security tests. DORA Art. 26 asks for threat-led penetration tests, and PCI DSS Req. 11.4 and 11.4.5 for penetration and segmentation tests. A Tumult run is none of these.
DORA in short
DORA here is the EU act. The DevOps “four keys” that share the name are in the metadata standard.
flowchart LR
accTitle: DORA and the Tumult evidence for it
accDescr: Runs of every kind give evidence toward the testing programme of Art. 24 and the tests of Art. 25. DR tests and manual records give evidence toward recovery and restore, Art. 11 and Art. 12. A threat-led penetration test under Art. 26 and a tested exit plan under Art. 28(8) are manual records. All of it feeds the DORA score and the evidence pack.
runs["Runs of every kind"] --> a24["Art. 24 and 25<br/>resilience testing"]
dr["DR tests and<br/>manual records"] --> a11["Art. 11 and 12<br/>recovery and restore"]
tlpt["A TLPT,<br/>a manual record"] --> a26["Art. 26<br/>TLPT"]
exit["An exit plan drill,<br/>a manual record"] --> a28["Art. 28(8)<br/>ICT third-party risk"]
a24 --> score["DORA score<br/>and evidence pack"]
a11 --> score
a26 --> score
a28 --> score
- Resilience testing, Art. 24 and Art. 25. Art. 25 sets no frequency of its own: the yearly test is Art. 24(6). The
testerof theregulatoryblock says whether the tester isinternalorexternal(Art. 24(4)). - TLPT, Art. 26. Financial entities that the competent authority identifies run a threat-led penetration test (TLPT) on live production systems at least every three years. A Tumult run is not a TLPT. It can help design the scenarios. Record a TLPT as a manual record of type
tlpt. - ICT third-party risk, Art. 28. The DORA score has a row for a tested exit plan (Art. 28(8)): a manual record of the drill that names
dora.art28.8. A run can test what happens when a provider fails or goes insolvent: name the plan scenariothird_party_failureof RTS 2024/1774 (Art. 25(2)(b), Art. 26(2)(b), Art. 26(4)). - Where the score fits. The DORA score shows the evidence per article and per business function, and an internal level from 1 to 5. No authority defines that level.

- Where the DR reports fit. The DR test report and the DR exercise report show each DR test against its RTO and RPO. The evidence pack holds the DORA matrix of the requirement registry. See Reports for an auditor.

Next
- Regulatory mapping: every control, its strength and the journal field that holds the evidence.
- DORA score: coverage per article and the plan scenarios.